Geothermal Ground Source Heat Pump for Centralized Heating&Cooling

Geothermal Ground Source Heat Pump for Centralized Heating&Cooling
Product Detailed
Geothermal Ground Source Heat Pump -For Centralized Heating, Cooling -As Air Conditioning -Saving Energy,High COP -CE,CRAA

Geothermal Ground Source Heat Pump for Centralized Heating&Cooling

Introduction: LTLHM(G)(R) Screw Compressors Water Source Heat Pump for central heating and cooling

-Water Source(Water to Water) Heat Pump(WSHP)

-Ground Source Heat Pump(GSHP)

-Geothermal Heat Pump(GHP)

Model Details:

MODELS: LTLHM(R)-35---LTLHM(R)-700

R407C with Screw Compressors

Heating Capacity: 142-2632KW; Cooling Capacity: 130-2340KW

MODELS: LTLHG(R)-55---LTLHG(R)-800

R134A with Screw Compressors

Heating Capacity: 198-2848KW; Cooling Capacity: 185-2800KW

1. Heating Only: for floor or radiator heating;

2. Heating and Cooling and domestic hot water: for fan coil heating in winter and cooling in summer and providing domestic hot water with DHW system(Heat Recovery Type);

3. High Efficiency(Energy Saving):

When Heating(Winter), unit receive heat power from ground & water, and centralize it by electric-drive compressor and heat exchange, then release with high temperature in the room.

COP 4.5-5.0 (Efficiency 1KW Power can get 5KW heating at condition of Water Side 15°C, User Side Hot Water 45°C); The Minimum water source side(As Groundwater, Surface Water, Close Loop Water etc.) temperature 10°C; The more higher of the water source side temperature, the COP will be more higher, and more energy saving;

When Cooling(Summer), unit get cooling power from ground/water, centralize it and transmit into the room. At the same time, heat in the room is transmitted into the ground/water, to realize the function of air conditioner.

COP 5.5-6.0 (Efficiency 1KW power can get 6KW cooling at condition of Water Side 18°C, User Side cooling Water 12°C); User Side Standard design cooling water outlet is 7°C;

Model Details:

R407C Models: LT   L   H   M   (R) --- 80

LT: LVTE Company Products Code/L: Screw Compressor/H: Heat Pump (Cooling&Heating)/M: R407C-Standard Type/80: Normal Cooling Capacity (USRT)

Working Design Standard Conditions:

1.Cooling Standard Conditions:condenser water inlet/outlet temperature18ºC/29ºC, evaporator water inlet/outlet temperature 12ºC/7ºC;

2.Heating Standard Conditions: condenser water inlet/outlet temperature 40 ºC /45 ºC, evaporator water inlet/outlet temperature 15 ºC /7 ºC;

3.Heat recovery equipments can be added.

Model Details:

 

 

R134a Models: LT   L   H   G   (R) --- 80

LT: LVTE Company Products Code/L: Screw Compressor/H: Heat Pump (Cooling&Heating)/G: R134a-High Temperature Output Type/80: Normal Cooling Capacity (USRT)

Working Design Standard Conditions:

1.Cooling Standard Conditions:condenser water inlet/outlet temperature18ºC/29ºC, evaporator water inlet/outlet temperature 12ºC/7ºC;

2.Heating Standard Conditions: condenser water inlet/outlet temperature 55ºC/60ºC, evaporator water inlet/outlet temperature 15ºC/7ºC; Max. Hot Water Output 65ºC;

3.Heat recovery equipments can be added.

 